Welcome to Iightstrade.com!

LED bay light

MOQ : piece

Lead Time : Days

Seller Support : Trade Authenticity Guaranteed & Accepting

Payment : L/C,T/T,Western Union, Money Gram, Credit Card, Paypal

Product details

Supply Ability

  • Warranty(Year):1 Year

Product Specifications

Product Description

Applications
Warehouse,stadium,shop,office and parking areas.
 
Description
B1 LED bay light is designed for variety of applications.Fashionable appearance and outstanding performance Creates attractive and comfortable environment. Fiti LED Lowbay has both of suspension and recessed types.
 
Features:
 1、Top quality LED source from Nichia;
2、Fashionable appearance;
3、Longer lifetime (>50,000 hours);
4、Excellent integration of heat sink,reflector,electric board and lens;
5、Easy installation low maintenance.
 
Benefits:
(1)、5 times longer lifetime than that of High pressure Sodium lamps and 10 times to Mercury lamps.
(2)、Power consumption reduces 72% relative to 250w High Pressure Sodium lamps and 53% to 150w ones.
(3)、Based on TCOO calculations,the payback duration is within 3 years.
 
Specification:

Ichnography:
Main Voltage/Frequency
200~240 V(AC)/50~60(Hz)
LED Power Consumption
70W ± 10%
LED Luminous Flux
>5000 lm
LED Efficiency
>80lm/W
Color Temperature (K)
3500/5100± 10%
Color Rendering Index
>70
Operating Temperature
-20℃~+50 ℃
Operating Relative Humidity
20%~80%
Lifespan (L70 life)
50000 hours
Dimensions (mm)
500(L)×350(W) ×192(H)
Weight
6.5 kg
IP (Ingress Protection)
IP20
Certification
CE,UL,RoHS compliance
Dimming Solution (Intelligent system)
N/A

Maintains at least 70% of initial lumen output
 
Photometrics data:
 

 
 
Different options for reflectors.

Actual spec is based on purchase order. The form is only for reference.
 
Specification:

Factors
Bay light
150W MH
Fiti B1 LED bay light
150W HPS
Lamp power consumption (watt)
150
70
150
System power consumpton (watt)
185
82
190
Lifespan (Hours)
8000
50000
10000
Color Rendering Index
65
>70
25
Comparison of energy consumption
Base on 100 pcs quantity
System power consumption (watt)
18500
8200
19000
Electricity consumption per day (kw-hr)
222
98
228
Annual consumption (kw-hr)
81030
35916
83220
*For 12 hours operation
Operation extra spending (5 years )
Base on EU area
Cost of energy consumption
$72927
$32324
$74898
Cost of lamp replacement
$6000
N/A
$4500
Cost of maintenance (Labor)
$3000
N/A
$3000
Cost of ballast replacement (1 time)
$4000
N/A
$4000
Total Spending
$85927
$32324
$86398

Average each product saves $500 after 5 years operation!!
Annual consumption x 5years x $ 0.18 USD (Base on European electricity rate)
$10 USD x 100 pcs x 3 times.
 

CO2 emission
CO2 emission per year (kg)
55100
24423
56590

 
Application data:

lnstallaticn Example
Lsolux Diagram
 
This simulation is based on the room of 18×10 meters and 3.5 meters high of ceiling.
B1
Average lllumination
3.5m height
4.5m height
5.5m height
Spacing: 2m
582
552
524
Spacing: 2.5m
413
389
370
Spacing: 3m
299
282
266

This data differs from variety of factors such as reflector ratio.

You May Like